Aquaguard Skid Mounted RO Plant

Introduction

Skid Mounted Reverse Osmosis Plants are designed and built to deliver water suitable for diverse utilization purposes and various industrial process requirements. They are ideal for small hotels, schools/ institutions, nursing homes, commercial establishments and light industries.

Features

SYSTEM FEATURES

  • Completely assembled / pre-piped / pre-wired
  • Auto start / stop based on water level in the tank
  • MCB for plant protection
  • Raw water pump integrated with plant
  • Microprocessor based control panel for ease of operation and inbuilt process logic
  • Blending cartridge provision to adjust taste / TDS and followed by ultra violet disinfection for total safety
  • Inbuilt protection to high pressure pump by way of low pressure switch / high pressure switch
  • Integrated pre-treatment module for removal of suspended solids along with pressure gauges
  • Robust high pressure pump in SS 304 construction
  • Automatic backwashing of filters available as premium range
  • Online rota-meter for measuring permeate flow
  • Membranes from GE / Hydranautics
  • PU coated MS skid & plated hardware
  • Glycerin filled SS pressure gauges for durability

Standard Instrumentation

  • Pressure Gauges
  • Level Switch
  • Rota Meter
  • Conductivity Meter
  • Pressure Switches

OPTIONS

  • Automatic backwashing of filters
  • pH correction system
  • Post UV system
  • Cleaning system
  • Post treatment system
  • Remote monitoring system

Raw Water Characteristics

  • Hardness: 200-500 ppm
  • Alkalinity: 200-300 ppm
  • Chlorides: 300-400 ppm
  • Nitrates: 20-40 ppm
  • Silica: 10-15 ppm
  • Total Dissolved Solids (TDS): 500-2000 ppm (max)

Limiting Conditions for RO Feed Water

  • Turbidity: < 5 NTU
  • Organics: Nil
  • Maximum Water Temperature: < 40° C
  • Iron: < 0.3 ppm
  • Fluoride: < 1 ppm
  • Silt Density Index (SDI): < 5 ppm
  • Oil & Grease: Nil
  • Free Chlorine: Nil

Meet our Water Expert

He will recommend a solution customised to your needs.

Technical Specifications
OPERATING SPECIFICATIONS UNIT RO - 100 RO - 250   RO - 500
Maximum Flow LPH 100 250   RO - 500
Average Flow LPH 100 250   RO - 400
Inlet TDS mg/l 500- 1500 (Max) 500 - 2000 (Max.) 500 - 2000 (Max.)
Permeate TDS mg/l < 150 < 150 < 150
Recovery % 20 20 30
SYSTEM SPECIFICATIONS UNIT RO - 100 RO - 250 RO - 500
Particulate Filter   10 Micron, 4'' x 20" - -
Activated Carbon Block   4''x20" - -
Pressure Sand Filter (PSF) Capacity LPH - 1000 1200
Activated Carbon Filter (ACF) Capacity LPH - 1000 1200
Antiscalant Dosing System   Yes Yes Yes
Antiscalant Dosing Tank Capacity Liters 20 20 20
Micron Cartridge Filter (PP)   5 Micron, 20" Long 5 Micron, 10" Long 5 Micron, 20" Long
High Pressure Pump (HPP)   1000 LPH, 1.1 kw 1000 LPH, 1.1 kw 1200 LPH, 1.1 kw
RO Membrane   4"x40" 4"x40" 4"x40"
UV   No Yes Yes
Plant Dimensions (lxwxht) mm 600 x 800 x 1640 1000 x 800 x 1700 1000 x 800 x 1700
Weight (Approximately) kg 200 250 310
Power Supply   415 V AC, 3 Phase, 4 Wire, 50 Hz
Technical specifications are subject to change without prior notice due to continuous product improvement